Physical●  1RU Fixed Form Factor●  Cisco Nexus 3064-X: 64 10 Gigabit Ethernet ports (48 SFP+ and 4 QSFP+)◦   48 SFP ports support 1 and 10 Gigabit Ethernet◦   4 QSFP ports support 4 x 10 Gigabit Ethernet or 40 Gigabit Ethernet each●  2 redundant power supplies●  1fan tray with redundant fans●  1 I/O module with management, console, and USB flash memory ports
Performance●  1.28-Tbps Switching Capacity●  Forwarding rate of 950 mpps●  Line-rate traffic throughput (both Layer 2 and 3) on all ports●  Configurable maximum transmission units (MTUs) of up to 9216 bytes (jumbo frames)
Hardware Tables And ScalabilityMAC Addresses128,000
Number Of VLANS4096
Spanning-Tree Instances●  Rapid Spanning Tree Protocol (RSTP): 512●  Multiple Spanning Tree (MST) Protocol: 64
ACL Entries●  2000 Ingress●  1000 egress
Routing Table●  16,000 Prefixes And 16,000 Host Entries●  8000 multicast routes
Number Of EtherChannels64 (With PC)
Number Of Ports Per EtherChannel32
Buffers9 MB Shared
Boot Flash Memory2 GB
PowerNumber Of Power Supplies2●  Cisco Nexus 3064-X: Redundant for AC and DC power
Power Supply Types●  AC (Forward And Reversed Airflow)●  DC (forward and reversed airflow)
Typical Operating Power●  Cisco Nexus 3064-X◦   143 watts (W; 64p with Twinax at 100% load; 2 power supply units [PSUs])◦   177W (64p with SR optics at 100% load; 2 PSUs)
Maximum Power●  Cisco Nexus 3064-X: 199W
AC PSUs●  Input voltage●  Frequency●  Efficiency ●  100 to 240 VAC●  50 to 60 Hz●  89 to 91% at 220V
DC PSUs●  Input voltage●  Maximum current●  Efficiency ●  -40 to -72 VDC●  33A●  85 to 88%
Typical Heat Dissipation●  Cisco Nexus 3064-X◦   488 BTU/hr (64p with Twinax at 100% load; 2 PSUs)◦   605 BTU/hr (64p with SR optics at 100% load; 2 PSUs)
Maximum Heat Dissipation●  Cisco Nexus 3064-X: 683 BTU/Hr
CoolingForward And Reversed Airflow Schemes:●  Forward airflow: Port-side exhaust (air enters through fan-tray and power supplies and exits through ports)●  Reversed airflow: Port-side intake (air enters through ports and exits through fan-tray and power supplies)Single fan tray with redundant fansHot swappable (must swap within 1 min)
SoundMeasured Sound Power (Maximum)●  Fan speed: 40% duty cycle●  Fan speed: 60% duty cycle●  Fan speed: 100% duty cycle ●  59.7 dBA●  66.4 dBA●  71.0 dBA
EnvironmentDimensions (Height X Width X Depth)●  Cisco Nexus 3064-X: 1.72 X 17.3 X 19.7 In. (4.4 X 43.9 X 50.5 Cm)
Weight●  Cisco Nexus 3064-X: 20.5 Lb (9.3 Kg)
Operating Temperature32 To 104°F (0 To 40°C)
Storage Temperature-40 To 158°F (-40 To 70°C)
Operating Relative Humidity●  10 To 85% Noncondensing●  Up to 5 days at maximum (85%) humidity●  Recommend ASHRAE data center environment
Storage Relative Humidity5 To 95% Noncondensing
Altitude0 To 10,000 Ft (0 To 3000m)

Ad to CartQuick View