Physical | ● 1RU Fixed Form Factor● Cisco Nexus 3064-X: 64 10 Gigabit Ethernet ports (48 SFP+ and 4 QSFP+)◦ 48 SFP ports support 1 and 10 Gigabit Ethernet◦ 4 QSFP ports support 4 x 10 Gigabit Ethernet or 40 Gigabit Ethernet each● 2 redundant power supplies● 1fan tray with redundant fans● 1 I/O module with management, console, and USB flash memory ports |
Performance | ● 1.28-Tbps Switching Capacity● Forwarding rate of 950 mpps● Line-rate traffic throughput (both Layer 2 and 3) on all ports● Configurable maximum transmission units (MTUs) of up to 9216 bytes (jumbo frames) |
Hardware Tables And Scalability | MAC Addresses | 128,000 |
Number Of VLANS | 4096 |
Spanning-Tree Instances | ● Rapid Spanning Tree Protocol (RSTP): 512● Multiple Spanning Tree (MST) Protocol: 64 |
ACL Entries | ● 2000 Ingress● 1000 egress |
Routing Table | ● 16,000 Prefixes And 16,000 Host Entries● 8000 multicast routes |
Number Of EtherChannels | 64 (With PC) |
Number Of Ports Per EtherChannel | 32 |
Buffers | 9 MB Shared |
Boot Flash Memory | 2 GB |
Power | Number Of Power Supplies | 2● Cisco Nexus 3064-X: Redundant for AC and DC power |
Power Supply Types | ● AC (Forward And Reversed Airflow)● DC (forward and reversed airflow) |
Typical Operating Power | ● Cisco Nexus 3064-X◦ 143 watts (W; 64p with Twinax at 100% load; 2 power supply units [PSUs])◦ 177W (64p with SR optics at 100% load; 2 PSUs) |
Maximum Power | ● Cisco Nexus 3064-X: 199W |
AC PSUs● Input voltage● Frequency● Efficiency | ● 100 to 240 VAC● 50 to 60 Hz● 89 to 91% at 220V |
DC PSUs● Input voltage● Maximum current● Efficiency | ● -40 to -72 VDC● 33A● 85 to 88% |
Typical Heat Dissipation | ● Cisco Nexus 3064-X◦ 488 BTU/hr (64p with Twinax at 100% load; 2 PSUs)◦ 605 BTU/hr (64p with SR optics at 100% load; 2 PSUs) |
Maximum Heat Dissipation | ● Cisco Nexus 3064-X: 683 BTU/Hr |
Cooling | Forward And Reversed Airflow Schemes:● Forward airflow: Port-side exhaust (air enters through fan-tray and power supplies and exits through ports)● Reversed airflow: Port-side intake (air enters through ports and exits through fan-tray and power supplies)Single fan tray with redundant fansHot swappable (must swap within 1 min) |
Sound | Measured Sound Power (Maximum)● Fan speed: 40% duty cycle● Fan speed: 60% duty cycle● Fan speed: 100% duty cycle | ● 59.7 dBA● 66.4 dBA● 71.0 dBA |
Environment | Dimensions (Height X Width X Depth) | ● Cisco Nexus 3064-X: 1.72 X 17.3 X 19.7 In. (4.4 X 43.9 X 50.5 Cm) |
Weight | ● Cisco Nexus 3064-X: 20.5 Lb (9.3 Kg) |
Operating Temperature | 32 To 104°F (0 To 40°C) |
Storage Temperature | -40 To 158°F (-40 To 70°C) |
Operating Relative Humidity | ● 10 To 85% Noncondensing● Up to 5 days at maximum (85%) humidity● Recommend ASHRAE data center environment |
Storage Relative Humidity | 5 To 95% Noncondensing |
Altitude | 0 To 10,000 Ft (0 To 3000m) |